Beams Document 1203-v0

DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]

Simulated Tevatron Closed Orbit Position Measurements in Short Gate Mode

Document #:
Beams-doc-1203-v0
Document type:
Note
Submitted by:
Robert K Kutschke
Updated by:
Robert K Kutschke
Document Created:
16 Jun 2004, 14:57
Contents Revised:
16 Jun 2004, 14:57
Metadata Revised:
07 Jul 2004, 08:36
Viewable by:
  • Public document
Modifiable by:
  • Same as Viewable by

Quick Links:
Latest Version

Abstract:
This note uses single turn Tevatron BPM data, taken with the modified Recycler Echotek boards in short gate mode, to simulate a closed orbit measurement. Two algorithms for adding the single turn data are explored, a vector sum of single turns and a scalar sum of single turns. As expected the vector sum has a poorer resolution by about a factor of two. The resolution is also plotted as a function of the number of turns using the simulated closed orbit measurement.