Abstract:
This paper discusses the implementation of abort gap monitoring at the Tevatron. The current system utilizes a fast gateable microchannel plate type photomultiplier tube from Hamamatsu, model number R5916U-50 (but with 3 stages of microchannel plates). There is one connected to each of the proton and pbar Synclite systems. The system can detect as few as 10^7 particles in the DC beam.