Abstract:
The MI DCCT along with two toroids are used to measure the NuMI beam intensity. A study was done to check their agreement by looking at data from the ACNET datalogger from Feb 18 until Mar 22. A 1% error was found between the two toroids, and a 4.24%, and 5.25% disagreement was found between the DCCT and the toroids. The calibration procedures were checked for the three devices, and candiates for the major sources of error were identified, and are being addressed.