Beams Document 2091-v1

DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]

BEAM BASED ALIGNMENT OF THE DEBUNCHER INJECTION SEPTUM

Document #:
Beams-doc-2091-v1
Document type:
Note
Submitted by:
Dave McGinnis
Updated by:
Dave McGinnis
Document Created:
08 Jan 2006, 19:25
Contents Revised:
08 Jan 2006, 19:25
DB Info Revised:
08 Jan 2006, 19:25
Viewable by:
  • Public document
Modifiable by:
Abstract:
This document describes the alignment procedure used for the Debuncher Injection Septum. This alignment was done on December 10, 2005. Because the injection septum is motorized, there are more variables than constraints in this procedure. Because of the additional variables, the key idea of this procedure was to constrain the vertical trajectory in the AP2 line to the center of the last three quadrupoles of the AP2 line
Files in Document:
Keywords:
antiproton aperture
DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]