Abstract:
This note presents a detailed look at flash data from MI State 5, mixed mode anti-proton production plus NUMI, in which there are seven injections followed by two extractions. The data is presented for two different configurations of the timing card, one in which the flash timing is armed by the BES and synced to the \$AA marker and a second in which the flash timing is both armed by and synced to the BES. In this study the turn-by-turn delay (house delay) was scanned from 0 to 1180 half-buckets, in steps of 5 half-buckets. The response of all eight flashes will be shown as a function of this delay. This note also studies the disruption of the NUMI batches following the extraction of the anit-proton production batch.
Files in Document:
Other Files:
Topics:
Notes and Changes:
This is (hopefully) the final version. Some figures have been dropped and others renumbered.