Beams Document 2254-v3

DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]

The Tevatron Ionization Profile Monitors

Document #:
Beams-doc-2254-v3
Document type:
Talk
Submitted by:
Andreas Jansson
Updated by:
Andreas Jansson
Document Created:
01 May 2006, 06:49
Contents Revised:
10 May 2006, 08:59
Metadata Revised:
10 May 2006, 08:59
Viewable by:
  • Public document
Modifiable by:

Quick Links:
Latest Version

Other Versions:
Beams-doc-2254-v2
09 May 2006, 14:03
Beams-doc-2254-v1
02 May 2006, 09:39
Abstract:
In designing an ionization profile monitor system for the Tevatron some novel approaches were taken, in particular for the readout electronics. This was motivated by the desire to resolve the individual bunches in both beams simultaneously. For this purpose, custom made electronics originally developed for Particle Physics experiments was used to provide a fast charge integration with very low noise. The various parts of the read-out electronics have been borrowed or adapted from the KTev, CMS, MINOS and BTev experiments. The detector itself also had to be modified to provide clean signals with sufficient bandwidth. The system design will be described along with the initial results.
Files in Document:
Associated with Events:
BIW06 held from 01 May 2006 to 04 May 2006 in Fermilab, Batavia, IL, USA
DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]