Beams Document 2388-v2

DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]

Thermal Calculation for MI8 Collimators

Document #:
Beams-doc-2388-v2
Document type:
Note
Submitted by:
Bruce C. Brown
Updated by:
Bruce C. Brown
Document Created:
10 Aug 2006, 19:44
Contents Revised:
01 Sep 2006, 11:17
Metadata Revised:
22 Apr 2008, 11:11
Viewable by:
  • Public document
Modifiable by:

Quick Links:
Latest Version

Other Versions:
Beams-doc-2388-v1
10 Aug 2006, 20:47
Abstract:
A collimation system for the Fermilab Booster to Main Injector transfer line (MI8 line) has been designed and installed. This system will remove particles in the beam halo from 8 GeV Booster beam before it arrives at the Main Injector. A pair of 5 ton collimators, with horizontal and vertical motion, is installed between the gradient magnets in half-cell 836 and an identical system is placed one cell away (about 90o in phase advance) at 838. The static and dynamic thermal response of this system to energy deposited by 8 GeV protons has been calculated to examine peak temperatures and temperatures at thermocouple locations. Results of these calculations will be used to establish temperature limits for device protection. We will explore the possibility of monitoring the integrated beam power lost to the collimators by measurement of the temperature rise integrated over the time of operation.

Files in Document:
  • MSWord (Beams-doc-2388.doc, 3.4 MB)
  • PDF (Beams-doc-2388.pdf, 644.2 kB)
Notes and Changes:
Updated reference for Beams-doc-2426