Systematic monitoring of residual radiation levels in the Main Injector tunnel have been carried out since Fall 2005 using a dual-range Geiger counter dosimeter with bar-code reading capability. Bar coded locations have been monitored periodically during operations and cool-down measurements during facility shutdown periods have been carried out. We will describe the bar-code tagging, meter operation, data storage and some results.