Beams Document 4692-v1

DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]

Loss History in Main Injector: LI619A-LI621 and LI101C-LI107

Document #:
Beams-doc-4692-v1
Document type:
Note
Submitted by:
Bruce C. Brown
Updated by:
Bruce C. Brown
Document Created:
28 Oct 2014, 14:49
Contents Revised:
28 Oct 2014, 17:50
DB Info Revised:
28 Oct 2014, 17:50
Viewable by:
  • Public document
Modifiable by:
Other Versions:
Abstract:
Various beam instrumentation devices have been or will be installed in the Main Injector near the Main Injector and Recycler injection regions from 101 through 104 and in the 620 straight section. The failure of one piece of electronics has alerted us to issues of radiation damage. Preparations are underway for documenting the radiation at locations where electronics currently exists or where additional electronics may be placed. Using the tools available, a summary of the Beam Loss Monitor (BLM) data for some of the loss monitors in the area is provided. Features of these losses are dominated by various changes in the configuration of the Main Injector and Recycler so these items will be documented.