Abstract:
A look at IPM and Charge0 data before and after the dogleg and ORBUMP changes. Investigate the beam width modulation at about ORBUMP turn off time scales using both the horizontal (x) IPM (calibrated) and the vertical (y) IPM (using x-calibration). Document the appearance of losses which are correlated with the beam width modulation. The losses appear to be the smallest with the current (4/23/03) Booster configuration.