Abstract:
Operation of the Fermilab Main Injector is sensitive to magnetic field differences due to hysteretic effects. Measurements using the beam are reported with various current ramps. This will provide magnetic field information for accelerator operations with better ramp control than is available from magnet test facility data. This makes possible improved low field reproducibility with mixed 120 GeV and 150 GeV operation of the Main Injector.
Files in Document:
Other Files:
Associated with Events:
PAC 2003 held from 12 May 2003 to 16 May 2003 in Portland, Oregon
Publication Information:
PAC2003 paper WPAB057.