Beams Document 6270-v2

DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]

Al Tag Radiation Studies for Instrumentation in the Main Injector

Document #:
Beams-doc-6270-v2
Document type:
Note
Submitted by:
Bruce C. Brown
Updated by:
Bruce C. Brown
Document Created:
13 Apr 2018, 11:00
Contents Revised:
13 Apr 2018, 18:23
Metadata Revised:
13 Apr 2018, 18:23
Viewable by:
  • Public document
Modifiable by:

Quick Links:
Latest Version

Other Versions:
Beams-doc-6270-v1
13 Apr 2018, 15:24
Abstract:
Radiation damage to electronics in accelerator tunnels may require using long cable runs to locations where radiation is sufficiently reduced. hen constraints such as cable capacitance, high voltages, and/or frequency response suggest having electronics in the tunnel, a study of the radiation loss environment may help identify suitable locations. Using Al Tag activation techniques, we measure the fluence of hadrons in regions of interest in the MI600 - MI100 tunnel locations. We lso have placed Al Tags adjacent to three gas ionization beam loss monitors which allows us a new calibration of their response.
Files in Document:
Other Files:
Notes and Changes:
Corrected labeling of final pictures.
DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]

DocDB Version 8.8.9, contact Beams Document Database Administrators