Abstract:
Two measurement procedures for the LCLS-II cryomodule cavity probe calibration at the LLRF front panel monitor are presented in this note for comparison. Both measurement procedures were repeated for cavities 1 and 4. The results of the two measurement procedures are presented, along with final measurement results for all eight cavities in the cryomodule.