Beams Document 82-v1
[
Fermilab at Work
] [
Accelerator Division
] [
Beams DocDB
] [
LARP
] [
LARP DocDB
] [
ProgDev DocDB
]
[
DocDB Home
] [
Search
] [
Last 20 Days
] [
List Authors
] [
List Topics
]
Summary of the Existing MR Beam Diagnostics for Use in Main Injector
Document #:
Beams-doc-82-v1
Document type:
Note
Submitted by:
Ruth A. Becker
Updated by:
Monica A Neuffer
Document Created:
27 Nov 2002, 11:04
Contents Revised:
01 Mar 1993, 00:00
DB Info Revised:
01 Mar 1993, 00:00
Actually Revised:
23 Jun 2003, 11:36
Viewable by:
Public document
Modifiable by:
Same as Viewable by
Other Versions:
Beams-doc-82-v0
27 Nov 2002, 11:04
Abstract:
A survey of the beam diagnostic devices reusable from the Main Ring and their existing operational limitations have been made. Possible places of using these devices in the Main Injector and their operational requirements have been investigated.
Files in Document:
pdf
(MI-0081.pdf, 292.6 kB)
Topics:
Main Injector
:
Beam Instrumentation
Main Ring
:
Beam Dynamics
Authors:
Chandrashekhara M. Bhat
David E. Johnson
Keywords:
main_injector
main_ring
beam_instrumentation
beam_loss
toriod
beam_loss_monitor
resistive_wall_monitor
Publication Information:
MI-0081
[
DocDB Home
] [
Search
] [
Last 20 Days
] [
List Authors
] [
List Topics
]
DocDB
Version 8.7.11, contact
Beams Document Database Administrators
Security, Privacy, Legal