Beams Document 960-v4

DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]

Strategies For Measuring Resolution of new BPM Electronics

Document #:
Beams-doc-960-v4
Document type:
Note
Submitted by:
Mark Fischler
Updated by:
Mark Fischler
Document Created:
06 Jan 2004, 14:00
Contents Revised:
09 Jan 2004, 09:07
Metadata Revised:
09 Jan 2004, 09:07
Viewable by:
  • Public document
Modifiable by:
  • Same as Viewable by

Quick Links:
Latest Version

Other Versions:
Beams-doc-960-v3
08 Jan 2004, 08:47
Beams-doc-960-v2
07 Jan 2004, 08:58
Abstract:
A statement in the requirements for the new BPM electronics is that the
differential resolution not exceed 7 microns (one sigma).
This note discusses how such a measurement can be done, and how accurately
sigma might be measured, given the availability
of only one prototype of the new BPM design.
The result is that sigma can be measured to 15% accuracy using a sequence of
35 3-bump measurements, or if 30% accuracy is adequate, a sequence of
14 3-bump measurements.