Beams Document 1453-v2
[
DocDB Home
] [
Search
] [
Last 20 Days
] [
List Authors
] [
List Topics
] [
List Events
]
Measuring and Adjusting Accumulator Tunes
Document #:
Beams-doc-1453-v2
Document type:
Note
Submitted by:
Brian E. Drendel
Updated by:
Brian E. Drendel
Document Created:
15 Nov 2004, 11:59
Contents Revised:
30 Apr 2020, 08:10
Metadata Revised:
30 Apr 2020, 08:10
Viewable by:
Public document
Modifiable by:
beams
Quick Links:
Latest Version
Other Versions:
Beams-doc-1453-v1
15 Nov 2004, 12:02
Abstract:
This document covers how to measure and adjust the Pbar Accumulator tunes. Some accelerator physics background is also provided.
Files in Document:
Measuring and Adjusting Accumulator Tunes
(Accumulator-tunes-2.htm, 116.2 kB)
pdf
(Accumulator-.pdf, 377.4 kB)
Other Files:
Spreadsheet to help calculate the tunes form the spectrum analyzer peak readings
(Manual-Accumulator-Tunes.xls, 19.0 kB)
Topics:
Antiproton Source
:
Instrumentation
Antiproton Source
:
Accumulator
Antiproton Source
:
Operations
Antiproton Source
:
Lattice
Antiproton Source
:
Beam Dynamics
Authors:
Brian E. Drendel
Keywords:
Tuning
Accumulator
Pbar
Antiproton
Operations
Publication Information:
The most recent version of this document is also availalbe online at
http://www-drendel.fnal.gov/TuningGuide/Accumulator-Tunes/Accumulator-tunes.htm
[