To bend the 8 GeV antiprotons on the Recycler design orbit, straight gradient magnets have been built to provide the design integral field on a straight path through the magnet as well as on the design orbit. This requires installation with a transverse displacement by $d/3$ at the magnet center where $d$ is the sagitta. The transverse alignment of the gradient magnets for the Fermilab Recycler Ring used a slightly different set of numbers which will be described. Bend effects of design sextupole fields and the fields from end shims will be calculated.