This NIM electronics module is configured and programmed to manage the phase locking of the Booster RF to the Frequency and phase of the Main Injector RF 3 ms before extraction of the beam from the Booster to the MI/Recycler. A previous version of the module has been in operation for a couple years. This version, improves the RF clock input circuits, does not require external cabling to connect the "Divide-by-32" RF signals to their phase detector, and replaces the LEMO IO connections with more reliable BNC connections. Additionally, a high speed serial interface like our newer VXI ACNET interface modules use has been included in order to provide adjustable parameters to the control room.