WORKING DRAFT ON TRANSVERSE EMITTANCE oacS - nOV 30, 2004 1. FW emittance OAC (Nate) a) create ACNET variables with for the current best lattice parameters for injection, flattop, low beta. Set them to the values in doc 1465, with the idea that they will eventually come from the measured twiss parameter database. Datalog and store in SDA Conditions case. ACNET variables with design lattice parameters? b) Remove emittance calculation from FE. Put this flying wire only emittance calculation into the OAC. Use ACNET lattice parameters. c) Keep the uncoupled emittance calculation for E11 and E17 using the SBD for dp/p in the OAC, use ACNET lattice numbers, but uncoupled approximation? d) Add new coupled emittance calculations to the OAC as defined in Doc 1465 and use the ACNET lattice numbers. Added--> e) Does anyone need emittances with design parameters? f) Have the OAC give the freshness number of the data it uses for its emittance calculations as an "OAC freshness number" so the two can be compared to look for synchronization problems. g) Get the new stuff into SDA and dataloggers 2) what to do with T46 - Nate will have a proposal tomorrow 3) Synclite OAC (Randy) a) part of FW OAC or separate? b) What to use for diffraction subtraction? c) Use ACNET lattice parameters d) do we also need emittances using design lattice parameters