Minutes of the 4 March 2011 Tevatron Dept Meeting https://indico.fnal.gov/conferenceDisplay.py?confId=4149 * Weekly Operation Summary (Jerry Annala) - The Tevatron delivered 41.6 pb^-1 to the experiments over the past week. There have been 8 HEP stores with initial luminosities between 180 and 345 ub^-1/s. Store 8534 was lost after only 1 hour due to a lightning-induced glitch of the magnet power bypass loop. Shot 8536 was lost during acceleration when TRF4 tripped off and resulted in a magnet quench. Shot 8543 was lost at the end of scraping when PAK3 pre- fired. The C4 BPMs have required reboots during many shot-setups; the Instrumentation folks suspect boards ned to be reseated in the crate. The D0 IP position was adjusted this week; we had to use "non-standard" bumps since some of the dipole correctors are running close to their limits. * Next Week's Shutdown Activities (All) - tasks include... - Magnet roll measurements - Reinstallation of vertical crystal collimator goniometer (with new cystal) - Installation of pixel detectors to image channeled beam - HLS maintenance - Fix heater on TRF1 cavity - Replace cracked fluorinert sight glass on separators - Other maintenance/inspections